malfunction | the reason | Method of exclusion |
Pump out of liquid | 1, the motor is not steering 2, lack of liquid storage pump 3, there is air leakage in the suction tube | 1, adjust the steering 2, add enough liquid 3, remove the gas |
ã€Pump does not absorb liquid】 | 1, the end of the valve is not open or blocked 2, suction stroke is too high or inhalation pipeline is too long 3, inhalation of impurities in the pipeline blocked | 1, calibrate or replace the bottom valve 2, reduce suction or shorten the pipeline 3, remove clogged debris |
ã€Insufficient pump flow】 | 1, impeller damage 2, inhalation or export part is blocked 3, lack of power speed is too low | 1, replace the impeller 2, remove clogged debris 3, check the motor speed up |
[Pump head inadequate] | 1, impeller damage 2, There is air in the conveying medium 3, speed is not enough | 1, replace the impeller 2, re-perfusion liquid or exclude air 3, check the motor speed up |
Noise or vibration | 1, pump shaft and motor shaft is not the same heart 2, the foot nut loose 3, suction stroke is too high | 1, correct the pump and motor concentricity 2, Tighten the bottom nut 3, reduce the installation height |
Bearing temperature is too high | 1, bearing damage 2, deterioration of grease dry or missing | 1, replacement 2, replacement, filling grease |
Pump Leakage | 1, mechanical seal damage 2, the connection bolts are loose | 1, replacement 2, tighten the various parts of the bolt |
Resistance Tube Band Sets,Resistance Tube Band,Resistance Tube Workout,Resistance Tube Set,resistance bands wholesale