Surface heat treatment is divided into two categories, one is chemical heat treatment, and the other is surface quenching and tempering heat treatment. The hardness test method is as follows:
1, chemical heat treatment Chemical heat treatment is the atom that penetrates the surface of a workpiece into one or more chemical elements, thereby changing the chemical composition, organization, and properties of the surface of the workpiece. After quenching and tempering at low temperature, the surface of the workpiece has high hardness, wear resistance and contact fatigue strength, while the core of the workpiece has high toughness.
The main technical parameters of the chemical heat treatment workpiece are the depth of the hardened layer and the surface hardness. Depth of hardened layer is still measured by Vickers hardness tester. The distance from the surface of the workpiece to the point where the hardness drops to 50HRC is detected. This is the effective hardening depth of chemical heat treatment of the workpiece surface hardness test and surface hardening heat treatment workpiece hardness testing is similar, can use Vickers hardness tester, surface Rockwell hardness tester or Rockwell hardness tester to detect, but the thickness of nitriding thicker Thin, generally not more than 0.7mm, then Rockwell hardness tester can no longer be used.
2, surface quenching and tempering heat treatment Surface quenching and tempering heat treatment is usually performed by induction heating or flame heating. The main technical parameters are surface hardness, local hardness and effective hardened layer depth. Vickers hardness tester can be used for hardness test, Rockwell or Rockwell hardness tester can also be used. The choice of test force (scale) is related to the effective hardened layer depth and the surface hardness of the workpiece. There are three hardness scales involved here.
Vickers hardness tester is an important means to test the surface hardness of the heat treatment workpiece, it can use 0.5 to 100kg of test force, test thin to 0.05mm thick surface hardening layer, its accuracy is the highest, can distinguish the heat treatment workpiece surface hardness The slight difference. In addition, the effective hardened layer depth is also detected by the Vickers hardness tester. Therefore, it is necessary to provide a Vickers hardness tester for the unit that performs the surface heat treatment process or uses a large number of surface heat-treated workpieces.
Surface Rockwell hardness tester is also very suitable for testing the hardness of surface quenched workpieces. The surface Rockwell hardness tester can be selected with three scales. It is possible to test various hardened workpieces with an effective hardening depth of more than 0.1 mm. Although the accuracy of the surface Rockwell hardness tester is not as high as that of the Vickers hardness tester, it has been able to meet the requirements as a means of quality control and inspection of the heat treatment plant. Moreover, it also has the characteristics of simple operation, convenient use, low price, rapid measurement, direct reading of hardness value, etc., and the use of surface Rockwell hardness tester can quickly and non-destructively detect each piece of surface heat-treated workpieces. This is important for metal processing and machinery manufacturing plants.
Rockwell hardness tester can also be used when the surface heat treatment hardening layer is thick. When the heat-treated hardened layer thickness is 0.4-0.8mm, the HRA ruler can be used. When the hardened layer thickness exceeds 0.8mm, the HRC ruler can be used.
The three hardness values ​​of Vickers, Rockwell, and Rockwell can be easily converted to each other and converted to standard, drawing, or user-desired hardness values. Corresponding conversion tables are given in the International Standard ISO, American Standard ASTM and Chinese Standard GB/T. The three conversion tables can be found in the technical information section of the Shenyang Star Website.
3, local heat treatment If the local hardness of the part is required to be higher, the partial quenching heat treatment may be performed by means of induction heating. Such parts usually have the location of the local quenching heat treatment and the local hardness value on the drawing. Hardness testing of parts is performed within the specified area. The hardness tester can use Rockwell hardness tester to test the HRC hardness value. If the heat treatment hardened layer is lighter, the Rockwell hardness tester can be used to test the HRN hardness value.
Hotel Lock
Product advantages:
1. When guests stay in the store, they only need to register at the front desk, and after completing the procedures, they will get a valid stay time proximity card. The guest can open his room freely when he gets the key with the house number, without having to open the door through the waiter.
2. Guests can rest assured to put their items in the room when they go out, and when guests return to the hotel, they can open the square tongue when they move in the room. At this time, it is safer. The floor attendant cannot open the door lock without the guest's permission (available in unexpected situations) Emergency card opened);
3. The hotel can use the data card to extract the door opening record in the lock and print it out as evidence to judge the authenticity of the accident. The smart card key is a multi-encryption key, which overcomes the characteristics of mechanical keys that are easy to copy and not portable, and is safer and more reliable for the hotel and guests.
4. Scientific and scientific hotel management. There are more than ten types of hotel smart card management systems, with different function cards, which can conveniently implement hotel management and improve the economic benefits of the hotel.
5. People who are away from home will give priority to choosing hotels with good image, sense of security and convenience when staying; smart card door locks can provide guests with the above enjoyment, bringing a continuous source of customers to the hotel, in real life hotels There may be situations where the guest`s stay is overdue and the deposit is insufficient or the room escape fee is maliciously owed, causing both parties to be unhappy or even friction with the guest, which will cause economic losses to the hotel and affect the hotel`s reputation to a certain extent;
6. The "effective stay time" of the smart card door lock can solve this problem well and clear your worries. The smart card key issued to the guest by the smart card electronic lock of our store cannot be copied, and the confidentiality is strong. The guest opens the door by himself without having to go through the floor attendant, which can greatly reduce the staff expenses of the hotel attendant and the corresponding comprehensive expenses.
Hotel Lock,Hotel Room Door Locks,Hotel Door Security Latch,Hotel Lock System
Dongguan Kaisijin Intelligent Technology Co., Ltd , https://www.oemsmartlock.com