Application range  |
Liquid: water; diesel; gasoline
|
Measured Value | Â |
Primary measured value  | Flow Rate |
Secondary measured value  | Volume flow  |
Features  |  |
Modular construction  | The measurement system consists of a flow sensor and a signal converter. It is available as compact and as separate version.  |
Compact version converter    |
N Type: Pulse output without local display |
A Type: 4-20mA Output without local display | |
B Type: Local Display; Lithium Battery Power; Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â No Output | |
C Type: Local Display; 24V DC Power; 4-20mA Output; Â Optional Function: Â
| |
Connection   |
Thread: DN4-DN50 |
Flange: DN15-DN200 (DIN, ANSI, JIS) | |
Wafer: DN15-DN100 | |
Measurement Ratio | Standard - 10:1; Optional: 20:1 |
Reference conditions  | Flow conditions similar to EN 29104  |
Medium: Water  | |
Electrical conductivity: ≥ 300 μS/cm  | |
Temperature: +10...+30°C / +50...+86°F  | |
Inlet section: ≥ 10 DN  | |
Operating pressure: 1 bar / 14.5 psig  | |
Flow Meter Accuracy  |
Standard: 1.0% of rate |
Optional:Â 0.5% of rate |
Temperature | Â |
Process temperature  | T1 Level: -20...+80°C  |
T2 Level: -20...+120°C  | |
T3 Level: -20...+150°C  | |
Ambient temperature  (all versions)  |
Standard (with aluminum converter housing):  |
-10…+55°C  | |
Storage temperature  | -20...+70° |
Pressure | Â |
 EN 1092-1  | DN100…DN200: PN 16  |
DN15…DN80: PN 25 | |
Other pressures on request  | |
ASME B16.5 Â | 1/2"...8": 150 lb RF Â |
Other pressures on request  | |
JIS Â | 1/2"...8": 10 K Â |
Other pressures on request  |
Installation   |
Take care that flow sensor is always fully filled  |
For detailed information see chapter "Cautions for Installation" Â | |
Flow direction   |
Forward |
Arrow on flow sensor indicates flow direction. Â | |
Inlet run  | ≥ 10 DN  |
Outlet run  | ≥ 5 DN  |
Sensor housing  | SS304 |  |
Other materials on request  |  | |
Flanges   |
SS304 | Â |
Other materials on request  |  | |
Rotor |  |  |
Standard: 2Cr13 | EN10088-3 Â Â Â Â Â Â 1.4021 | X20Cr13 |
AISI 420 | Â | |
BS 420S37 | Â | |
JIS SUS410J1 | Â | |
Optional: CD4MCu | DN15…DN80 |  |
Bearings and Shaft | Tungsten Carbide | Â |
Converter Housing | Standard: polyurethane coated die-cast aluminum  |
Flange | Â |
EN 1092-1 Â | DN15...200 in PN 6...40 Â |
ASME  | 1/2"…8" in 150 lb RF  |
JIS  | 1/2"…8" in 10...20K  |
Design of gasket surface  | RF  |
 | Other sizes or pressure ratings on request  |
Thread | DN4…DN50 in PN63 |
Nominal Diameter | Standard Flow Range  | Extended Flow Range  | |
(mm) | (in.) | (m3/h) | (m3/h) Â |
4 | 0.15 | 0.04 to 0.25 | 0.04 to 0.4 |
6 | 0.25 | 0.1 to 0.6 | 0.06 to 0.6 |
10 | 0.4 | 0.2 to 1.2 | 0.15 to 1.5 |
15 | 0.5 | 0.6 to 6 | 0.4 to 8 |
20 | 0.75 | 0.8 to 8 | 0.45 to 9 |
25 | 1 | 1 to 10 | 0.5 to 10 |
32 | 1.25 | 1.5 to 15 | 0.8 to 15 |
40 | 1.5 | 2 to 20 | 1 to 20 |
50 | 2 | 4 to 40 | 2 to 40 |
65 | 2.5 | 7 to 70 | 4 to 70 |
80 | 3 | 10 to 100 | 5 to 100 |
100 | 4 | 20 to 200 | 10 to 200 |
125 | 5 | 25 to 250 | 13 to 250 |
150 | 6 | 30 to 300 | 15 to 300 |
200 | 8 | 80 to 800 | 40 to 800 |
Model Suffix Code |  |  |  | Description | ||||||
LWGY- | Â | Â | Â | Â | Â | Â | Â | Â | Â | |
Diameter |  |  |  |  |  |  |  |  |
Three Digitals; for example: 010: 10 mm;              015: 15 mm; 080: 80 mm;              100: 100 mm                |
|
Converter | N | No display; 24V DC; Pulse Output | ||||||||
A | No display; 24V DC; 4-20mA Output | |||||||||
B | Local display; Lithium Battery Power; No output | |||||||||
C |
Local display; 24V DC Power; 4-20mA Output; Â Optional backup power: Lithium Battery |
|||||||||
C1 |
Local display; 24V DC Power; 4-20mA Output; Modbus RS485 Communication Optional backup power: Lithium Battery |
|||||||||
H |
Local display; 24V DC Power; Â 4-wire 4-20mA Output & HART Communication |
|||||||||
Accuracy | ||||||||||
05 | 0.5% of Rate | |||||||||
Flow Range | S | Standard Range: refer to flow range table | ||||||||
W | Wide Range: refer to flow range table | |||||||||
Body Material | S | SS304 | ||||||||
L | SS316 | |||||||||
Explosion Rating | N | Safety Field without Explosion | ||||||||
E | ExdIIBT6 | |||||||||
Pressuring Rating | Â | N | Standard | |||||||
H(x) | Customized Pressure Rating | |||||||||
Connection | Â | Â | -DXX |
DXX: D06, D10, D16, D25, D40 D06: DIN PN6; D10: DIN PN10 D16: DIN PN16; D25: DIN PN25 D40: DIN PN40 |
||||||
-AX |
AX: A1, A3, A6 A1: ANSI 150#; A3: ANSI 300# A6: ANSI 600# |
|||||||||
-JX |
JX: J1, J2, J4 J1: JIS 10K; J2: JIS 20K; J4: JIS 40K |
|||||||||
-TH | Thread; DN4…DN50 | |||||||||
Fluid Temperature |  |  |  | -T1 | -20...+80°C | |||||
-T2 | -20...+120°C | |||||||||
-T3 | -20...+150°C |
Knitted Storage Box
This knitted storage box can be used to store items. When there are too many items in the room and there is nowhere to put them, a storage box can perfectly solve these problems. It can not only help us to store things that are not commonly used, but also has the function of sorting. After sorting the items according to their uses, they can be easily found next time they are used.
Our knitted storage box is more exquisite and beautiful than other storage boxes. It has retro craftsmanship and can also play a decorative role in the room. The size and model can be customized according to your requirements, and we support mass production.Yacheng Knitting Co., Ltd. can mass produce customized high-quality knitted garments, including sweaters, Custom Knit Sweaters, Knitted Pants, Knitted Skirt , Knitted Shoes, Knitted Scarves and Knitting Blanket. If you need to order knitted products, please contact us.
Knitted Storage Box,Knitting Needle Storage Box,Knitting Wool Storage Box,Large Knitting Storage Box
DongGuan Yacheng Knitting Co., Ltd , https://www.oemknittingyc.com